[1] |
L. H. Han, W. Li, R. Bjorhovde , “Developments and Advanced Applications of Concrete-Filled Steel Tubular (CFST) Structures: Members,”Journal of Constructional Steel Research, Vol. 100, pp. 211-228, 2014
doi: 10.1016/j.jcsr.2014.04.016
|
[2] |
S. Ellison and W. Tizanj, “Behaviour of Blind Bolted Connections to Concrete Filled Hollow Sections,” Structural Engineer, Vol. 82, No. 22, pp. 16-17, 2004
|
[3] |
A. Y. Elghazouli, C. Málaga-Chuquitaype, J. M. Castro , et al., “Experimental Monotonic and Cyclic Behaviour of Blind-Bolted Angle Connections,” Engineering Structures, Vol. 31, No. 11, pp. 2540-2553, 2016
doi: 10.1016/j.engstruct.2009.05.021
|
[4] |
J. Wang, L. Zhang, B. F. S. Jr , “Seismic Response of Extended End Plate Joints to Concrete-Filled Steel Tubular Columns,” Engineering Structures, Vol. 49, No. 2, pp. 876-892, 2013
doi: 10.1016/j.engstruct.2013.01.001
|
[5] |
J. F. Wang, L. H. Han, B. Uy , “Behaviour of Flush End Plate Joints to Concrete-Filled Steel Tubular Columns,” Journal of Constructional Steel Research, Vol. 65, No. 4, pp. 925-939, 2009
doi: 10.1016/j.jcsr.2008.10.010
|
[6] |
J. Wang and L. Chen, “Experimental Investigation of Extended End Plate Joints to Concrete-Filled Steel Tubular Columns,” Journal of Constructional Steel Research, Vol. 79, No. 12, pp. 56-70, 2012
doi: 10.1016/j.jcsr.2012.07.016
|
[7] |
W. Tizani and D. J. Ridley-Ellis, “The Performance of a New Blind-Bolt for Moment-Resisting Connections, ” Taylor & Francis, 2003
|
[8] |
T. Pitrakkos and W. Tizani, “Experimental Behaviour of a Novel Anchored Blind-Bolt in Tension,” Engineering Structures, Vol. 49, No. 2, pp. 905-919, 2013
doi: 10.1016/j.engstruct.2012.12.023
|
[9] |
W. Tizani, A. Al-Mughairi, J. S. Owen , et al., “Rotational Stiffness of a Blind-Bolted Connection to Concrete-Filled Tubes using Modified Hollo-Bolt,” Journal of Constructional Steel Research, Vol. 80, No. 1, pp. 317-331, 2013
doi: 10.1016/j.jcsr.2012.09.024
|
[10] |
W. Tizani, Z. Y. Wang, I. Hajirasouliha , “Hysteretic Performance of a New Blind Bolted Connection to Concrete Filled Columns under Cyclic Loading: An Experimental Investigation,” Engineering Structures, Vol. 46, No. 1, pp. 535-546, 2013
|
[11] |
W. Tizani and T. Pitrakkos, “Performance of T-Stub to CFT Joints using Blind Bolts with Headed Anchors,” Journal of Structural Engineering, 2015
|
[12] |
M. R . Bahaari and A. N. Sherbourne, “Behavior of Eight-Bolt Large Capacity End PlateConnections,” Computers & Structures, Vol. 77, No. 3, pp. 315-325, 2000
doi: 10.1016/S0045-7949(99)00218-7
|
[13] |
L. H. Han, G. H. Yao, X. L. Zhao , “Tests and Calculations for Hollow Structural Steel (HSS) Stub Columns Filled with Self-Consolidating Concrete (SCC),” Journal of Constructional Steel Research, Vol. 61,No. 9, pp. 1241-1269, 2005
|
[14] |
SACJointVenture (SAC), ProtocolforFabrication, Inspection, Testing, and Documentation ofBeam-column ConnectionTestsandOtherExperimental Specimens, Rep. No. SAC/BD-97/02, SACJointVenture, Sacramento, California, USA, 1997
|
[15] |
GB 50017-2003, ChineseDesignCodeofSteelStructure, Ministry of Housing and Urban-Rural Development of the People’s Republic of China, Beijing, China, 2003
|
[16] |
CEN, Eurocode 3: Design of steel structures-Part 1-8: Design of joints. ENV1993-1-8, Eurocode 3: Design of steel structures-Part 1-8: Design of joints. ENV1993-1-8, Brussels: CEN; 2005
|