A Preventive Maintenance Model Subject to Sequential Inspection for a Three-Stage Failure Process
|
|
Cao Xiaoxiao,Guo Chao,Xiong Huasheng,Li Duo,Huang Xiaojin
|
|
| |
Table 2 Parameters used in numerical example
|
|
| ${{\lambda }_{1}}$ | 15.83 | ${{k}_{1}}$ | 1.47 | | ${{\lambda }_{2}}$ | 9.61 | ${{k}_{2}}$ | 1.95 | | ${{\lambda }_{3}}$ | 6.02 | ${{k}_{3}}$ | 2.81 | | $\alpha $ | 0.4 | ${{c}_{mi}}$ | 8 | | ${{c}_{ma}}$ | 20 | ${{c}_{cr}}$ | 3000 | | ${{c}_{ir}}$ | 400 | ${{c}_{or}}$ | 200 | | ${{T}_{om}}$ | 200 | | |
|
|
|