Design and Study of Performance Characteristics of Flat Wall Rectilinear 3D Diffuser with Square Inlet and Rectangular Outlet
|
Manish Kumar, Shailendra Kumar
|
|
|
Table 6 Readings taken for calibrating three-hole probe |
|
i | | Average static pressure in mm of the inclined water column | Average static pressure in mm of the vertical water column | in (Pa) | % | 1 | 0.5781 | -22.00 | -19.13 | -187.01 | 75.29 | 2 | 0.6624 | -17.25 | -15.07 | -147.27 | 79.67 | 3 | 0.7468 | -14.00 | -12.18 | -118.98 | 82.77 | 4 | 0.8312 | -11.25 | -9.77 | -95.49 | 85.29 | 5 | 0.9156 | -9.50 | -8.17 | -79.84 | 87.03 |
|
|
|